Vol. 7 No. 5 (2026): September 2026
Open Access
Peer Reviewed

Quantification of Occupational Safety Risk in a Boiler Area through Integration of Quantitative Fault Tree Analysis and HIRADC: A Case Study in the Creamer Industry

Authors

Muhammad Ubaidillah , Moh. Jufriyanto , Mega Rahayu H

DOI:

10.46729/ijstm.v7i5.1471

Published:

2026-09-26

Downloads

Abstract

The boiler area is among the most hazardous workplaces in manufacturing because it simultaneously involves thermal energy, high pressure, and electrical energy. Applications of Fault Tree Analysis (FTA) in the Indonesian occupational safety literature commonly stop at the qualitative level, serving as a cause-mapping tool that yields neither event probabilities nor a measurable control priority ranking. This study aims to quantify occupational accident risk in the boiler area of PT Sehat Alam Segar by integrating quantitative FTA with Hazard Identification, Risk Assessment, and Determining Control (HIRADC). Fifty-three basic events across three top events were quantified by converting a frequency-anchored likelihood scale into per-exposure probabilities, then evaluated using two fault tree structures: an all-OR structure (Model A) and a defence-in-depth structure incorporating AND gates (Model B). Model A overestimated event frequency by 9.6–65.8 times relative to actual incident data for 2024–2025, whereas Model B remained within a factor of 1.49–1.86 and showed no significant difference from the actual data (Poisson test, p = 0.061 and p = 1.000). Model B top event probabilities were 1.044 × 10⁻¹ per steam-line maintenance job, 1.221 × 10⁻⁴ per operating day (4.36 × 10⁻² per year), and 1.245 × 10⁻² per electrical job. Fussell–Vesely analysis showed that human and management factors contributed 51.6% of structural importance. The HIRADC control design based on the ISO 45001:2018 hierarchy reduced the mean risk score from 8.79 to 3.83 (Wilcoxon signed-rank, Z = 6.360; p < 0.001; r = 0.874), eliminated all Extreme-category events, and was estimated to lower top event probabilities by factors of 17–266. This reduction is a model-based estimate rather than a post-implementation measurement. These findings confirm that a fault tree structure which does not represent protective layers yields systematically erroneous risk estimates.

References

[1]. Alizadeh, S.S., & Moshashaei, P. (2015). The Bowtie method in safety management systems: A literature review. Scientific Journal of Reviews, 4(9), 133–138.

[2]. Bell, J. L., & Williams, J. C. (2018). Evaluation and consolidation of the HEART human reliability assessment principles (pp. 3–12). https://doi.org/10.1007/978-3-319-60645-3_1

[3]. Cox, L.A., Jr. (2008). What's wrong with risk matrices? Risk Analysis, 28(2), 497–512. https://doi.org/10.1111/j.1539-6924.2008.01030.x

[4]. Ekoanindiyo, FA, Yohanes, A., Prihastono, E., & Hayati, EN (2021). The fault tree analysis method approach in occupational health and safety and its impact on productivity. Journal of Industrial Systems Engineering, 7(1), 20–25. https://doi.org/10.33884/jrsi.v7i1.4456

[5]. Health and Safety Executive. (2001). Reducing risks, protecting people: HSE's decision-making process. HSE Books. ISBN 0-7176-2151-0.

[6]. Henny, H., Budi, AHS, Andriyansyah, M., Ar Rozzak, MR, Baru, MM, & Masek, A. (2025). Hazard identification, risk assessment, and determining control (HIRADC) for workplace safety in manufacturing industry: A risk-control framework complete with bibliometric literature review analysis to support Sustainable Development Goals (SDGs). ASEAN Journal for Science and Engineering in Materials, 4(2), 267–284.

[7]. International Organization for Standardization. (2018a). ISO 31000:2018 Risk management — Guidelines.

[8]. International Organization for Standardization. (2018b). ISO 45001:2018 Occupational health and safety management systems — Requirements with guidance for use.

[9]. Ministry of Manpower of the Republic of Indonesia. (2016). Regulation of the Minister of Manpower of the Republic of Indonesia Number 38 of 2016 concerning Occupational Safety and Health of Aircraft Power and Production.

[10]. Mahyunis, M., Effendi, Z., & Asrianto, F. (2023). Analysis of work accident risks at the boiler station at the PTPN VI-South Solok Unit PKS using the HIRARC method. IRA Journal of Mechanical Engineering and Its Applications (IRAJTMA), 2(2), 37–46. https://doi.org/10.56862/irajtma.v2i2.57

[11]. Marsudi, S. (2021). Boiler system failure risk analysis using fault tree analysis. Marine Science and Technology Research, 81–84. https://doi.org/10.62012/sensistek.v4i1.19751

[12]. OREDA. (2015). OREDA: Offshore and onshore reliability data handbook (6th ed.). OREDA Participants.

[13]. Dutch East Indies Government. (1930). Steam Act 1930 (Stoom Ordonnantie 1930) and Steam Regulations 1930 (Stoom Verordening 1930).

[14]. Rahmanto, I., & Ihsan Hamdy, M. (2022). Analysis of employee occupational accident risk using the Hazard and Operability (HAZOP) method at PT PJB Services PLTU Tembilahan. Journal of Applied Industrial Technology and Management, 1(2), 53–60. https://doi.org/10.55826/tmit.v1i2.15

[15]. Republic of Indonesia. (1970). Law Number 1 of 1970 concerning Occupational Safety.

[16]. Standards Australia/Standards New Zealand. (2004). AS/NZS 4360:2004 Risk management. Standards Australia, Sydney & Standards New Zealand, Wellington.

[17]. Vesely, W.E., Goldberg, F.F., Roberts, N.H., & Haasl, D.F. (1981). Fault tree handbook (NUREG-0492). US Nuclear Regulatory Commission.

[18]. Wiradara, AG, Nirmala G., F., & Saptaputra, SK (2024). Analysis of potential OHS hazards using the HIRARC method in the boiler section of the Nii Tanasa Kendari PLTU in Lalonggasumeeto District, Konawe Regency in 2023. Detector: Journal of Health Science Research Innovation, 2(1), 243–262. https://doi.org/10.55606/detector.v2i1.3352.

Author Biographies

Muhammad Ubaidillah, Program Studi Teknik Industri, Fakultas Teknik, Universitas Muhammadiyah Gresik, Jawa Timur 6112, Indonesia

Author Origin : Indonesia

Moh. Jufriyanto, Program Studi Teknik Industri, Fakultas Teknik, Universitas Muhammadiyah Gresik, Jawa Timur 6112, Indonesia

Author Origin : Indonesia

Mega Rahayu H, Program Studi Teknik Industri, Fakultas Teknik, Universitas Muhammadiyah Gresik, Jawa Timur 6112, Indonesia

Author Origin : Indonesia

Downloads

Download data is not yet available.

How to Cite

Ubaidillah, M., Moh. Jufriyanto, & Mega Rahayu H. (2026). Quantification of Occupational Safety Risk in a Boiler Area through Integration of Quantitative Fault Tree Analysis and HIRADC: A Case Study in the Creamer Industry. International Journal of Science, Technology & Management, 7(5), 690–710. https://doi.org/10.46729/ijstm.v7i5.1471